Modelo de la unidad | HWGTH- | 10S | 12S | 15S | 18S | 18D | 20D | 22S | 22D | 28D | 35S | 35D | 40D | 50T | 70D | 80D | 90D | 110T | 120T | 130T |
Circuito de agua | Capacidad de refrigeración | kW | 9.1 | 10.9 | 13.7 | 16.4 | 16.4 | 18.2 | 20.0 | 20.0 | 25.5 | 31.9 | 31.9 | 36.4 | 45.5 | 63.7 | 72.8 | 81.9 | 100.1 | 109.2 | 118.3 |
Potencia de entrada | kW | 2.2 | 2.6 | 3.3 | 3.9 | 3.9 | 4.3 | 4.8 | 4.8 | 6.0 | 7.6 | 7.6 | 8.6 | 10.8 | 15.0 | 17.2 | 19.3 | 23.6 | 25.7 | 27.9 |
Capacidad de calefacción | kW | 12.8 | 15.4 | 19.2 | 23.1 | 23.1 | 25.6 | 28.2 | 28.2 | 35.9 | 44.8 | 44.8 | 51.2 | 64.0 | 89.6 | 102.4 | 115.2 | 140.8 | 153.6 | 166.4 |
Potencia de entrada | kW | 2.6 | 3.2 | 3.9 | 4.7 | 4.7 | 5.2 | 5.7 | 5.7 | 7.3 | 9.1 | 9.1 | 10.4 | 13.0 | 18.2 | 20.7 | 23.3 | 28.5 | 31.1 | 33.7 |
Volumen de la fuente de agua | m³/h | 2.0 | 2.4 | 3.0 | 3.5 | 3.5 | 3.9 | 4.3 | 4.3 | 5.5 | 6.8 | 6.8 | 7.8 | 9.7 | 13.6 | 15.5 | 17.5 | 21.3 | 23.2 | 25.2 |
Agua subterránea | Capacidad de refrigeración | kW | 10.0 | 12.0 | 15.0 | 18.0 | 18.0 | 20.0 | 22.0 | 22.0 | 28.0 | 35.0 | 35.0 | 40.0 | 50.0 | 70.0 | 80.0 | 90.0 | 110.0 | 120.0 | 130.0 |
Potencia de entrada | kW | 2.1 | 2.5 | 3.1 | 3.7 | 3.7 | 4.1 | 4.5 | 4.5 | 5.7 | 7.1 | 7.1 | 8.1 | 10.2 | 14.2 | 16.2 | 18.2 | 22.3 | 24.3 | 26.3 |
Capacidad de calefacción | kW | 10.5 | 12.6 | 15.8 | 18.9 | 18.9 | 21.0 | 23.1 | 23.1 | 29.4 | 36.8 | 36.8 | 42.0 | 52.5 | 73.5 | 84.0 | 94.5 | 115.5 | 126.0 | 136.5 |
Potencia de entrada | kW | 2.8 | 3.3 | 4.2 | 5.0 | 5.0 | 5.5 | 6.0 | 6.0 | 7.7 | 9.6 | 9.6 | 11.0 | 13.7 | 19.1 | 21.9 | 24.6 | 30.0 | 32.8 | 35.5 |
Volumen de la fuente de agua | m³/h | 1.0 | 1.2 | 1.5 | 1.7 | 1.7 | 1.9 | 2.1 | 2.1 | 2.7 | 3.3 | 3.3 | 3.8 | 4.8 | 6.6 | 7.6 | 8.5 | 10.4 | 11.3 | 12.3 |
Circuito de agua subterránea | Capacidad de refrigeración | kW | 9.9 | 11.9 | 14.9 | 17.8 | 17.8 | 19.8 | 21.8 | 21.8 | 27.7 | 34.7 | 34.7 | 39.6 | 49.5 | 69.3 | 79.2 | 89.1 | 108.9 | 118.8 | 128.7 |
Potencia de entrada | kW | 2.2 | 2.6 | 3.3 | 3.9 | 3.9 | 4.3 | 4.7 | 4.7 | 6.0 | 7.5 | 7.5 | 8.6 | 10.7 | 15.0 | 17.1 | 19.2 | 23.5 | 25.6 | 27.7 |
Capacidad de calefacción | kW | 7.8 | 9.4 | 11.7 | 14.1 | 14.1 | 15.6 | 17.2 | 17.2 | 21.9 | 27.3 | 27.3 | 31.2 | 39.0 | 54.6 | 62.4 | 70.2 | 85.8 | 93.6 | 101.4 |
Potencia de entrada | kW | 2.8 | 3.3 | 4.1 | 5.0 | 5.0 | 5.5 | 6.0 | 6.0 | 7.7 | 9.2 | 9.2 | 10.5 | 13.1 | 18.4 | 21.0 | 23.6 | 27.0 | 29.5 | 31.9 |
Volumen de la fuente de agua | m³/h | 2.1 | 2.5 | 3.2 | 3.8 | 3.8 | 4.2 | 4.6 | 4.6 | 5.8 | 7.3 | 7.3 | 8.3 | 10.4 | 14.5 | 16.6 | 18.7 | 22.8 | 24.9 | 26.9 |
recuperación de calor ① | Capacidad de recuperación de calor | kW | 11.6 | 13.9 | 17.4 | 20.8 | 20.8 | 23.1 | 25.4 | 25.4 | 32.4 | 40.4 | 40.4 | 46.2 | 57.8 | 80.8 | 92.4 | 103.9 | 127.0 | 138.5 | 150.0 |
Caudal de agua | m³/h | 1.3 | 1.5 | 1.9 | 2.3 | 2.3 | 2.5 | 2.8 | 2.8 | 3.5 | 4.4 | 4.4 | 5.0 | 6.3 | 8.7 | 10.0 | 11.2 | 13.7 | 14.9 | 16.2 |
Temperatura de salida del agua | ºC | 55 | | | | | | | | |
Dimensiones de la tuberíara de salida del agua | | DN25 | DN25 | DN32 | DN32 | DN32 | DN32 | DN32 | DN32 | DN32 | DN32 | DN32 | DN40 | DN40 | DN50 | DN50 | DN65 | DN65 | DN65 | DN65 |
Caída de presión del agua | kPa | ≤ 50 | ≤ 70 | | | | | | | |
Potencia | AC380C-3PH-50Hz |
Volumen de impulsión de agua | m³/h | 1.8 | 2.1 | 2.6 | 3.1 | 3.1 | 3.5 | 3.8 | 3.8 | 4.9 | 6.1 | 6.1 | 6.9 | 8.6 | 12.1 | 13.8 | 15.5 | 19 | 20.7 | 22.4 |
Cantidad de compresores | | 1 | 1 | 1 | 1 | 2 | 2 | 1 | 2 | 2 | 1 | 2 | 2 | 3 | 2 | 2 | 2 | 3 | 3 | 3 |
Tipo de compresor | Scroll Tipo |
Tipo de Refrigerante | R22 |
Tipo de intercambiador de calor | Axial y tubos | Casco y tubo |
Caída de presión del agua | kPa | ≤ 50 | ≤ 75 |
Dimensiones de la tubería de la unidad | Parte de la impulsión | | DN25 | DN32 | DN32 | DN40 | DN50 | DN65 |